Push the Silence button when the pump is running. The 2.4Ghz network must use WPA or WPA2 security. Check out theZoeller YouTube Channelfor Webinars, Tips, Trainings, and Product Videos! Check battery. sump pump system (25 pages), 12 volt dc battery backup pump (12 pages), Preassembled sump pump system with battery backup 12 v dc battery backup system with 115 v ac powered sump pump model m53 or m98 (25 pages), Multi-stage turbine effluent pumps (8 pages), Sewage/effluent/sump/dewatering (6 pages), Battery backup pedestal sump pump (8 pages), Manual will be automatically added to "My Manuals", Water Pump Zoeller AQUANOT SPIN 508 Installation Instructions Manual, Water Pump Zoeller Aquanot 508 Installation Instructions Manual, Water Pump Zoeller 503 Installation Manuals, Water Pump Zoeller AQUANOT 508 Fit Installation Instructions Manual, Water Pump Zoeller AquaNot 508 Fit Installation Instructions Manual, Water Pump Zoeller ProPak 508/53 Installation Instructions Manual, Water Pump Zoeller 5030 Series Owner's Manual, Water Pump Zoeller AquaNot 507 Key Installation Instructions Manual, Water Pump Zoeller 5054 Installation Instructions Manual, Water Pump Zoeller 53 Series Installation Instructions Manual, Water Pump Zoeller 55/59 Series Installation Instructions Manual, Water Pump Zoeller 55 Series Installation Instructions Manual. Most routers have a firewall built into them. For example, the DC Pump LED will stay Yellow after pumping water, alerting the homeowner of a DC pump-run event. Disconnecting the high water float will cause the pump to run. Check all connections for leaks. If this condition exists, the incoming water. In most installations, the pump runs intermittently and the battery life is extended accordingly. Do, not use primary pump circuit. This will silence the alarm. The controller will automatically charge and maintain the battery in a way designed to extend battery life. Water powered emergency backup These times are based on continuous pumping at 8 (2.4 m) of static head. (b) The battery light will be yellow when charging. The float switch can be moved on the discharge pipe, or the rubber stops can be adjusted as necessary. Reset all alarms when you are finished. Flashing LEDs for conditions such as bad/disconnected battery or power outage, for example, cant be cleared by Silence/Reset. It is recommended that the pit be 18" (45.7 cm) in diameter or larger to. If the signal is questionable, your network may not be able to provide a stable connection for the Fit. Charger is also cURus and cCSAus approved. (c) Fill the sump with water to the on level for the DC pump. When the captive screen opens (see Figure C in next section), use the Wifi Scan button to find the Wifi network you want the Fit to use, select it from the list provided at the bottom of the screen (you may need to scroll), and type the Passphrase in the field. These conditions must be remedied to eliminate the LED indicator. The controller will recognize the difference between a pump that is pumping air vs. a pump that is pumping water. If the operational float was never installed, the alarm and red flashing Float Status LED will occur for 4 hours and then turn off. Screw check valve assembly into the primary pump discharge. (f) Float switch was not on for more than 1 second. in septic tanks to pump effluent or in sewage pits to pump sewage. If either float switch is missing/unplugged, it will create an immediate alarm condition. Like most internet connected devices, the Fits WiFi connectivity should be used behind a secure firewall. Made from non-corrodible polyethylene. Pump will stop running once battery is below minimum voltage threshold. A pen or toothpick or similar is required to press the Z Contol button (See Figure A). Double check that you know the correct password and exactly how it is spelled, including capitalization. Instructions for connecting directly are provided below under Use Your Mobile Device Or Computer To Connect Directly To The Fit Controller. After 1-second splash activation prevention delay the pump will turn on, the alarm will sound, and the light will alert of high water. Take care that the intake of the DC pump is set above the intake of the primary pump. Repair and service of your DC backup system should be performed by an, 5. or pit peculiarities and is secured so the pump will turn "on" and "off". (a) Check for low battery. Also consider the Aquanot Fit 508 Systems, which can add remote access and mobile notifications through the Z Control Cloud platform. If the operational float is held on while there is no water to pump, the controller will turn the pump on and off a few times before running the pump continuous. Some of these by-products can produce a rotten egg odor. Replace if necessary. As a safety measure each electrical outlet should be. The controller must be within 8 (2.4 m) of a 115 V wall outlet and within 6 (1.8 m) of pump and basin. The top rubber stop is usually not needed. Testing for ground. These instructions are below under Use the Mobile App. Test the installation for leaks by running water into the sump, allowing for normal operation of the primary pump. Make sure the 115 V electrical supply circuit is equipped with fuses or, DC emergency pumps are designed for handling clear water. Plug the controller and the primary pump into the wall outlet. If water was pumped, the Yellow DC Pump LED and alarm will remain on, indicating that the pump ran and pumped water. If you are certain that no CO is being produced, a charging battery may be producing gaseous by-products capable of causing the CO detector to activate. Do not operate in > 80 F environment. It is the owner's responsibility to check the battery and battery, connection at least once a month. The LED will now be off, indicating the Fit is in AP Mode. Inspect your pump. The pump will continue to run until the operational float is deactivated. This could take up to a minute or so. We offer both a water/acid deep-cycle battery and a maintenance-free AGM battery which can run the pump continuously for over 5 hours. Make sure there is a properly grounded 115 V receptacle available. If an update is taking place, the Z Control LED will flicker for up to 1 minute while the update is downloaded. The primary sump pump and the controller should be on separate circuits. If the operational float is down, and the DC pump is underwater, the pump will run until the float lowers and the pump is no longer pumping water, or the run timer expires. The battery will indicate its condition when the controller has DC power. Firmware Updates:The Fit is capable of OTA, or over the air firmware updates. Further, advanced float logic enables the controller to sense other pumping issues such as a stuck float, allowing the system to take actions to prevent damage to equipment. Testing for ground. All electrical and safety codes must be followed including the National. (e) Push the Silence/Reset button. BATTERY CASE: The included battery case will accommodate maximum battery dimensions of 13 L x 7-1/2 W x 9-1/2 H (33 cm L x 19 cm W x 24 cm H) and fits all group size 27, 29 and 31 batteries. If so, 2 things will happen: On the setup screen (see Figure C), press the WiFi Scan button, scroll down to see the list of WiFi signals found, and choose the WiFi network you want the Fit to use for internet connectivity. For example, the controller is able to recognize potential air lock situations and remedy with an on/off/on/off/on routine proven to purge the problematic air from the pump. (g) Make sure discharge piping is not blocked. In order to help prevent false activation, Zoeller Pump Company recommends moving the battery as far away from the CO detector as possible or, if necessary, venting the battery to the exterior. Clean if required. Press the slotted end of the discharge tee onto the check valve and secure with a hose clamp. Actual times will vary depending on static head, volume of water entering the pit, and the condition of the battary. If the operational float is removed/unplugged, there will be an alarm and a red flashing Float Status LED until silenced or remedied. To use multiple batteries, order extra battery case with hookup wire (P/N 10-5184). 2. If fuse is blown, replace with 30 amp automotive blade fuse. Enter the passphrase for the network you chose in the field indicated. Perform these test to be sure everything works as expected. accommodate both a primary and a DC backup pump. (c) Check for low battery. Select a location for the battery and the controller. its SSID) and its password. The top rubber stop is not needed unless the on level needs to be lowered. As one of the United States oldest independently owned pump manufacturers, the company brings an abundance of experience that benefits contractors and end users. Are you a contractor looking for a reliable pumping solution for residential applications? A 100+ amp hour battery will provide approximately 5.5 hours or more of continuous pumping time in a sump pump installation with 8 (2.4 m) of head pressure. Smart reporting to the cloud provides the ultimate peace of mind. Risk of electric shock. Use the Mobile App (iOS and Android) Before you begin: These basic instructions will not detail every step, but provide an overview of what the app will do. These pumps have not been investigated for use in swimming pools and marine areas. A deep-cycle, 12 volt, 90 amp-hour or larger marine battery is recommended. Check out theZoeller YouTube Channelfor Webinars, Tips, Trainings, and Product Videos! Select this, and be sure your device displays a check mark or similar indicator that you are connected to the Fits local network. Do not use. Run water into the sump until the DC backup pump is activated by the operational float switch. The Fit offers true redundancy for pump operation that competitors products do not have.Before leaving the installation site, the installer must initiate a Reset by holding the Silence button for 3 seconds. The self-testing technology ensures the pump is ready to perform and contributes to its long-term reliability. Battery box will accommodate a maximum battery size of 13-1/2 (34.3 cm) Length x 7 (17.8 cm) Width x 9-1/2 (24.1 cm) Height. The Fit controller powers up expecting both switches to be connected. Check for obstruction in pump preventing impeller from rotating. The advanced technology hardware and firmware in the Fit controller will recognize, attempt to remedy, and alarm for many conditions that have not previously been possible. Zoeller uses a normally open operational float switch, and a normally closed high water float switch. (b) If immediate usage is required, remove and replace dead battery with a fully recharged battery. For best cooling, install wall mount configuration. A quick up/down of a switch will not turn the pump on because the controller is designed with splash activation protection. If there is an operational float fault diagnosed by the controller, you may notice that it no longer turns the pump on and off. Parts that fail within the warranty period, that inspections determine to be defective in material or workmanship, will be repaired, replaced or remanufactured at Manufacturers option, provided however, that by so doing we will not be obligated to replace an entire assembly, the entire mechanism or the complete unit. This returns the firmwares device configuration to the state in which it left the factory. The pump will turn off once water is pumped lower than the operational float. These materials should be retained for future, 1. Also, some of these by-products can cause a CO detector to falsely activate. If the primary pump is installed, disconnect power. Make certain the clamp is tight on the pipe to avoid slippage. To perform a Factory Reset, hold the Silence and Test buttons together. The alarm can be silenced by pressing the Silence button. Know what your WiFi network is named (i.e. Both primary and backup systems are now ready for use. DO NOT USE AN EXTENSION CORD. equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is, encouraged to try to correct the interference by one or more of the following. Ensure that the off level of the float is 1 (2.5 cm) minimum above the outlet of the DC backup pump. This will prevent the most common troubleshooting issues. After 1 second splash activation prevention delay, the DC backup pump will run, and the alarm will sound after 1 more second. Locate the Fits Device ID on the top sticker. The location must be within 6 (1.8 m) of the control box and battery. It is recommended that the pit be 18 (45.7 cm) in diameter or larger to accommodate both a primary and a DC backup pump. Make sure the 115 V electrical supply circuit is equipped with fuses or circuit breakers of proper capacity. Batteries contain acid, and caution must be taken when handling. TE: Discharge piping must be 1-1/2 SCH 40 PVC. Take immediate action for personal safety as recommended in the CO detector literature. All Zoeller Pump products are made in the USA using 95% U.S. content, ensuring exceptional quality and maximum reliability. Be sure all switches, pump, battery and AC connections are good before the Factory Reset. Soapy water is recommended as a lubricant. Hold silence button for 3 seconds to reset the Fit controller.
Sitemap 27