Wash the parts in warm, soapy water and rinse in fresh water. Questions? NOTE: Press buttons and quickly release them to slowly advance the display. It appears as a small cloudy yellow, orange, or reddish suspended particles. To drain the softener: Automatic Electronic DiagnosticsThis water softener has a self-diagnostic function for the electrical system (except input power and/or water meter). Up moves the display ahead; down sets the time back. 72) & 1 ea. Leave an air gap of 1-1/2 between the end of the hose and the drain. Remember to fill your water softener with Morton Americas #1 Brand of Water Softener Salt! Sediment is fine, foreign material particles suspended in water. Verify brine draw from the brine tank by shining a flashlight into the brinewell and observing a noticeable drop in the liquid level. Simply dial 1- 8864WATER (1-888-649-2837) for assistance, or visit www.mortonwatersofteners.com. WARRANTOR WILL NOT BE LIABLE FOR ANY INDIRECT, INCIDENTAL, SPECIAL, CONSEQUENTIAL, OR PUNITIVE DAMAGES OF ANY KIND, NATURE, OR DESCRIPTION WHATSOEVER. RECHARGE NOW will flash during the regeneration. Purchase a compression fitting (1/4 NPT x 1/2 in. DO NOT remove the material from inside the tank. Generally, these irons are removed from water by filtration. In this example, you would use 30 for your hardness number. Then, holding the nozzle & venturi housing with one hand, unscrewthe cap. Add Water and Salt to the Salt Storage Tank. *Let sit for 60 seconds max, turn water on full for 10 minutes to flush the Sani-System out of the unit. Program the SoftenerWhen the power supply is plugged into the electrical outlet, the model code and a software version number (example: J3.9), are briefly shown in the display. Take a broom handle, or as a tool, and hold it next to the water softener. For the Standard model, use only one gallon of the solution with your unit and discard the rest per Sani-System instructions. If not already done, put a light coating of silicone grease on the single bypass valve o-rings. This creates a bigger cavity for the salt and is one of a few ways to add salt.Step 4: Remove top cap.Step 5: Add the correct amount of tablesaltinto the top for your softener.- One full 26 oz. Put the bypass valve(s) into the bypass position. The warranty does not apply to any defect, malfunction or failure arising from, relating to or caused by: (I) operation at water pressures which exceed 125 psi or at water temperatures which exceed 20F; (ii) repairs made by others than, or without the consent of, Warrantor or if the product has been subject to abuse, misuse, neglect, tampering, accident or damage by circumstances beyond warrantors control; (iii) products damaged or abused in shipment without fault of Warrantor; (iv) non-residential installations; (v) defects or failures due to misapplication, abuse, improper installation or abnormal conditions of temperature, humidity, abrasives, dirt or corrosive matter; (vi) unusual force f nature such as, but not limited to, flood, hurricane, tornado or earthquake; and (vii) products which have been in any way tampered with, modified or altered. If the dash shows, the switch is open. avoid salt bridging. Be sure the water softener is in the soft water (service) cycle (no water pressure at nozzle & venturi). Press the UP or DOWN buttons to set the present time. Do not attempt to treat water over 120F. Be sure the brinewell cover is on.NOTE: In humid areas, it is best to keep the salt storage level lower, and to refill more often to avoid salt bridging. Be sure to use the included power supply and plug it into a nominal 120V, 60 Hz household outlet that is in a dry location only, grounded, and properly protected by an overcurrent device such as a circuit breaker or fuse. Electronic Control Board (PWA), Models M20, M27, M30 & MC30, Reply. Be sure the hard water supply pipe goes to the water softener valve inlet side. For this reason, sanitizing as follows issuggested* when installing. The error code will return if the problem was not corrected. For example, assume your water is 20 gpg hard and contains 2 ppm iron. These tests represent the maximum possible efficiency that the system can achieve. Set Salt LevelThe water softener has a low salt indicator light to remind you to refill the storage tank with salt. Resin Tank, 8 x 35, Models M20 & M27, Reply. This gap is needed to prevent the backflow of sewer water into the water softener. This warranty gives you specific legal rights, and you may have other rights which vary from state to state. Close the shut-off valve on the houses main water pipe, near the water meter or pressure tank. Install the brine tank overflow grommet and elbow into the 13/16 diameter hole in the back of the salt. Always add if less than 1/4 full. Fully open two or more softened cold water faucets nearby the water softener, located downstream from the water softener. This information is retained by the computer from the first time electrical power is applied to the electronic controller. NOTE: The electronic control display must show a steady time (not flashing). Press the SELECT button once again to display a flashing 25 and the word HARDNESS. When completed (in about 2 hours), full water conditioning capacity is restored.NOTE: Avoid using hot water while the softener is regenerating, because the water heater will refill with bypass hard water. The timeof day that the automatic recharge cycle begins may be changed as follows: When this feature is ON, the water softener will operate at salt efficiencies of 4000 grains of hardness per pound of salt or higher (May recharge more often using smaller salt dosage but more regeneration water). Avoid installing in direct sunlight. This is a good time for the recharge to start in most households because water is not in use. If an incorrect model code is displayed, the softener will operate on incorrect configuration data. Install a #4 copper wire across the removed section of the main water pipe, securely clamping it at both ends (see Figure 14) parts not included. Step 6. Set Time of DayIf the words PRESENT TIME do not show in the display, press the SELECT button until they do. Materials used to make the unit will not infect or contaminate your water supply, and will not cause bacteria to form or grow. Carefully push into the bridge in several places to break it. Lubricate the O-ring seal with silicone grease and locate it in place. Do not return the water softener to store. NOTE: Be sure all 3 tabs of the clip go through the matching holes on the water softener valve inlet or outlet, and fully into the channel on the single bypass valve. Add 5 to the hardness number for each 1 ppm of iron. Step 1:Perform a back-flush. Separate the softener from the plastic installation adaptors, or from the bypass valve. To turn on the Salt Efficiency Feature, follow the instructions in the Salt Efficiency section of this manual. Remove the top cover to expose the valve and observe cam and switch operation during valve rotation. Call Toll Free 1-888-64 WATER (1-888-649-2837) or visit www.mortonwatersofteners.comWhen you call, please be prepared to provide the model and serial number, found on the rating decal, located on the rim below the salt lid hinges. Home MORTIN MORTIN Water Softener Instruction Manual, Water SoftenerModels M20, M27, M30, M34 & MC30How to install, operate and maintain your Demand Controlled Water Softener. This water softener will not remove colloidal iron.In some instances, treatment may improve colloidal iron water. Bypass valves allow you to turn off the water to the softener for maintenance if needed, but still have water in house pipes. To return the softeners valve to the service position, press the RECHARGE button. Press the UP or DOWN buttons to set the present time. Press and hold the SELECT button until the model code (see table on page 5) shows in the display. Forboth optionsDO NOT REMOVE top cap or head. For best results use Morton Clean and Protect or Morton Clean and Protect Plus Rust Defense Pellets in your water softener. Immediately after taking, the sample is clear. Without brine, the resin bed is not recharged and hard water will result. This water softener will not remove ferric or bacterial iron. If an error code shows, first press the SELECT button to enter the diagnostic display. Hold the buttons down for fast advance. Press the SELECT button three times, so that SET TIME Fr appears in the display (See Figure 42). To avoid the loss of small parts, we suggest you keep the small parts in the parts bag until you are ready to use them. Step 5: After the recommend amount of time, turn the water off and hook the softener back up.Note: If Back-flush and Re-gen are done together, perform theBack-flush processfirst. Open salt lid, remove the brinewell cover, and pour about 3 oz. To change the length of the Backwash: Low Salt Light / Clean ReminderWhen the water softener is connected to electrical power, the light on the control panel will operate as follows: This is a reminder to use Morton MWSC Water Softener Cleanser three times a year. A flexible drain hose is not allowed in all localities (check your plumbing codes). Step 2: Use thefemale/female adapter (not labeled) to the outlet of the softener. box of iodized/non-iodized salt for the Standard model.- Two full 26 oz. Also, inspect and note any damage to the shipping carton. hen completed, full water conditioning capacity is restored. Then, carefully push the broom handle straight down into the salt. Step 1. Customizing Features / Options (Model M34). 72), Turbine & Support Assembly, including 2 O-Rings (See Key No. If you wish to turn the Salt efficiency feature ON ( icon will show in the display), follow the instructions on this page. You can use either of these two options if draining water from theunit is required. Slowly and gently, tip it over until the rim rests on the wood block with the inlet and outlet over the drain. The softener is shipped withthis feature set OFF. Press the SELECT button once ore to complete the initial programming. Excessive sun heat may cause distortion or other damage to metallic parts. minimum tube) and 1/2 tubing from your local hardware store. Remove the brinewell cover and, using a flashlight, observe fill water entering the tank. Trace the water flow direction to be sure hardwater is to the inlet. This small component creates the suction to move brine from the brine tank, into the resin tank. Air Gap RequirementsA drain is needed for the water discharged from the valve during the softeners regeneration cycle (See Figure 3). The one year warranty period, on all parts other than the salt storage tank and fiberglass mineral tank, can be extended to five (5) years from the date of purchase if you use Morton MWSC Water Softener Cleanser on your system. Press the SELECT button once again to display a flashing 2:00 AM and the words RECHARGE TIME. This iron is visible. 25,500 @ 8.0 lbs. Your Morton Water Softener has a High Efficiency feature with an ON or OFF setting. Step 1: Turn off the water supply.Step 2: Disconnect inlet andoutlet hose from thesoftener.Step 3: You can drain water by tilting unit over or turning it upside down with the head/cap ON. Call Toll Free 1-888-64 WATER (1-888-649-2837) or visit www.mortonwatersofteners.comWhen you call, please be prepared to provide the model and serial number, found on the rating decal, located on the rim below the salt lid hinges. When using the softener to reduce Ferrous (clear water) iron, add 5 grains to the hardness setting for every 1 ppm of Ferrous (clear water) iron. CAUTION: The house cold water pipe (metal only) is often used as a ground for the house electrical system, The 3-valve bypass type of installation, shown in Figure 8, will maintain ground continuity. Cleaning the Nozzle & VenturiA clean nozzle & venturi (See Figure 44) is a necessity for the water softener to work properly. Morton Water Softener Salt Pellets are made with a time-release formula that works with your softener to help prevent mineral buildup and keep your homes pipes and appliances working at their best. Remove and discard (or recycle) all packing materials. Total iron is the sum of the contents. Use a floor drain, laundry tub, sump, standpipe, or other options (check your local codes). A licensed plumber shall be used for this installation. Forboth optionsDO NOT REMOVE top cap or head. If water does not enter the tank, look for an obstructed nozzle, venturi, fill flow plug, brine tubing, or brine valve riser pipe. Use one or both of our premium formula pellets in any water softener for the best results. Light flashing, with the time of day shown in the display The salt monitor system indicates a low salt level and needs to be set. Founded in 2004, we are the leading developer of portable water softening and water deionization products. Undue stress from misaligned or unsupported plumbing may cause damage to the valve.Complete the inlet and outlet plumbing for the type of pipes you will be using. The screen in Figure 17 appears, with CLEAn flashing in the display when four months have elapsed on thesystems timer since start-upor the last reset. Open all faucets to drain all water from house pipesNOTE: Be sure not to drain water from the water. Fully open the main water supply valve. Use of any water softener additive rather than Morton MWSC will invalidate any extended warranty coverage. Step 2:Perform the regeneration process Step 4. The water softener works on 24V DC electrical power, supplied by a direct plug-in power supply (included). Always install the water softener between the water inlet and water heater. ), you must drain all water from it to stop possible freeze damage. Inlet / Outlet Plumbing OptionsAlways install either a single bypass valve (provided), as shown in Figure 7, or, if desired, parts for a 3 valve bypass system (not included) can be purchased and assembled, as shown in Figure 8. Power Outage MemoryIf electrical power to the softener is interrupted, the time display is blank, but the electronic controller keeps the correct time for several hours. Do not scratch, misshape, etc., surfaces of the nozzle & venturi. European Directive 2002/96/EC requires all electrical and electronic equipment to be disposed of according to Waste Electrical and Electronic, Colloidal and inorganically bound iron (ferrous or ferric). Replace the brinewell cover. Measure, cut to the needed length, and connect the 3/8 drain line (provided) to the water softener valve drain fitting. Restart the Water HeaterTurn on the electricity or fuel supply to the water heater and relight the pilot, if applicable. This may initiate more frequent recharges. remove the material from inside the tank. 34,900 @ 14.5 lbs. Do not use this system to treat water that is microbiologically unsafe or of unknown quality without adequate disinfection upstream or downstream of the system. During regeneration, the word RECHARGE NOW will flash on the screen. Press the SELECT button twice, so that bA TIME appears in the display (See Figure 27). 11,100 @ 2.2 lbs. Once draining has been completed, flip the unit back upright and tap the black base against the ground a few times to get the resin to fall back down into the bottom of the tank. Ferric (red water), and bacterial and organically bound irons are insoluble. Close the inlet and outlet valve in a 3 valve bypass system, and open the bypass valve. To restore the ground, do the following: 1. If your home is equipped with a backflow preventer, an expansion tank must be installed in accordance with local codes and laws. Place the single bypass valve or 3 valve bypass in the bypass position. Move the softener close to the drain. After the recharge has completed, fully open a cold water faucet, downstream from the softener, and allow 50 gallons of water to pass through the system. When installing this unit in the State of California, you MUST turn his setting to the ON position, which may initiate more frequent charges. If you want to change the recharge start time, press the. Set the present time, hardness, etc., as described on pages 13 & 14 (for Models M20, M27, M30 & MC30) or pages 16-18 (for Model M34). Avoid elevating the hose more than 8 feet above the floor. If you have questions regarding a Morton water softener or MWSC, need assistance with installation or troubleshooting, wish to order a part, or report a warranty issue, we are just a phone call away. To have fully conditioned hot water immediately, wait until the initial recharge (Step 12) is over. Step 1: Disconnect both hoses and turn the unit upside down and allow water to drain from inlet/outlet. Your Morton Water Softener has a High Efficiency feature with an ON or OFF setting. Do not allow the ofteners weight to rest on the inlet and outlet fittings or they may break. The maximum allowable inlet water pressure is 125 psi. The current time of day will show in the display. Morton Water Softener Installation & Operation Manual. NOTE: If - - shows in the display, press the UP or DOWN button until the model code (see table n age 5) shows in the display. Plugin the Power SupplyDuring installation, the water softener wiring may be moved or jostled from the place. The light will stop flashing unless the system is also low on salt (see above). NOTE: Check local plumbing and electrical codes for proper installation of the ground wire. 73 & 74, Nozzle & Venturi Assembly (includes Key Nos. Be sure AM or PM is correct. For best results use clean grades of water softener salt. Install Valve Drain HoseNOTE: See valve drain options on pages 7 & 8. Plug the water softeners power supply into an electrical outlet that is not controlled by a switch and. These systems are not intended for treating water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the systems. If you want water in the house pipes again, reopen the shut-off valve on the main water pipe. NOTE: Inlet and outlet are marked on the water softener valve. Run water until there is a steady flow from the opened faucets, with no air bubbles. However, during shipping, storage, installation, and operation, bacteria could get into the unit. A floor drain, close to the water softener, is preferred. This is a good time for the recharge to start in most households because water is not in use. Overtightening may break the cap or housing. Variable Salt Dose: The salt dose is selected by the electronic controls at regeneration time based on the amount needed. Allow the softener to rinse for a few minutes to flush out any brine that may remain in the resin tank from the brining cycle test. Press and hold SELECT for 3 seconds until 000 shows in the display, then release. Set Water Hardness Number. This can easily be corrected by performing a special regeneration process. When power is restored, you must reset the present time only if the display is flashing. If you want to change the recharge start time, press the. Then, salt will not dissolve in the water to make brine. If daytime pressure is over 80 psi, nighttime pressure may exceed the maximum. EXTEND YOUR WARRANTY: Use MortonMWSC Water Softener CleanserThe factory warranty for your water softener is shown below. Carefully remove the two large plastic clips (you will use them). Press and hold the SELECT button until one of the screens in Figure 21 is displayed. Set them aside to prevent damage. If the storage tank is full of salt, it is difficult to tell if you have a salt bridge. You may damage the tank. When completed, full water conditioning capacity is restored. Before placing the unit in storage or being idle for extended periods: 1. Push the bypass valve body toward the softener (as shown in Figure 15) and carefully remove the large holding clips at the softener inlet and outlet. Press and hold the RECHARGE button until the words RECHARGE NOW flash on the display. Protect the Water Softener from FreezingIf the softener is installed where it could freeze (summer cabin, lake home, etc. Sanitizing the SoftenerCare is taken at the factory to keep your unit clean and sanitary. This is a reminder to use Morton MWSC Water Softener Cleanser three times a year. Other pipe approved for use with potable water. Run the drain hose (or a rigid line) to the floor drain. Set it on a solid, level surface. The salt level scale, on the brinewell inside the tank, has numbers from 0 to 8 (See Fig. It is typically less than the efficiency due to individual application factors including water hardness, water usage, and other contaminants that reduce the softeners capacity. Efficiency rated softeners have a rated salt efficiency of not less than 3,350 grains of total hardness exchange per pound of salt (based on sodium chloride) and shall not deliver more salt or be operated at a sustained maximum service flow rate greater than its listed rating.

Sitemap 7