Use a glove or tissue. leica cassette histology ipc ZRG Medical closeout auctions on DOTmed.com. Replacing the fuses 62 90 90 91 Fig. Operation 5.1 Control panel functions The control panel consists of a membrane keyboard with six pressure-sensitive keys (four of them with an LED, two LED displays and a two-figure sevensegment display. Cleaning and Maintenance Instructions for storage (continued) Likewise, clean the removed location plate (70) with the sealing lip with (clean) alcohol and a cleaning swab (89) (Fig. Upon pressing the button: 1 short beeping sound Magazine empty/tray stack full: 2 short beeping sounds In case of error: 5 short beeping sounds When ending the head cleaning: 5 short beeping sounds Back panel of instrument 60 Remote alarm 56 Fig. 65). 32). Ready-to-print software available. Check configuration of serial port of the PC and reboot the PC. Use no liquid in this area! Important! 7. 4. Fig. Phone: 800-650-0632Email: info@QRlogix.com, PathTelligence, LLCQRlogix4531 Samuel StSarasota, FL 34233, Use left/right arrows to navigate the slideshow or swipe left/right if using a mobile device, Customer accounts enabled in your Store Admin. 8. Cleaning and Maintenance Instructions for storage (continued) Push a (new) cleaning cartridge as far as it will go into the slot (Fig. 72 + 3 Fig. Each tray holds up to 10 cassettes. Call 248-215-5394 or email tech@rankinwarehouse.com, 21.5" W x 25.6" D x 25.7" H (without magazine), max. Sakura Tissue-Tek Autowrite Slide Printer, Sakura Tissue-Tek Autowrite Cassette Printer. Make sure to read these instructions, even if you are already familiar with the operation and use of other products. 3. 4 32 33 30 33 The enlarged detail shows the correct location of the collar screw once the unload station has been locked in place correctly. Ink-jet technology Before replacing the flash bulb, switch off the printer and unplug the instrument from power supply. 4. 57). 24 First insert a shielding glass (85) into the two holders (86) (Fig. Windows 2000 and XP do not contain the PORTS page. histology ipc ips Safety The safety and caution notes in this chapter must be observed at all times. 7. In stock repair parts ship same day if ordered before 12pm EST (M-F), TO ADD MULTIPLE ITEMS TO YOUR QUOTE, PLEASE FILL QTY FIELD THEN CLICK ON "ADD TO QUOTE", All Reagents, Chemicals, Solvents, & Solutes, Prints on standard smooth-faced cassettes with 35 to 45 angles with either lid on or lid off, no adjustments needed, Windows 10/Vista/7/8 (32 bit and 64 bit), 360 x 360 dpi / 180 x 180 dpi, adjustable, Instrument disassembled down to the frame, Panels, chassis and internal surfaces stripped and prepped for painting. Exchanges (if applicable)We only replace items if they are defective or damaged. Push the lever (69) upwards, then remove the red location plate (70) with the sealing lip (Fig. Cleaning and Maintenance 6.2 Cleaning the print head Preparing the printer The print head must be cleaned manually once a week or if the message "15" is displayed. Settings for the serial interface incorrect or the instru- Check cable connection to the PC. Every instrument undergoes a systemized, rigorous, down-to-the-framerefurbishment process to rebuild each instrument to its original specifications and intended use. The Leica IP C and IP S systems are second generation printers for the labeling of all common specimen cassettes and glass slides with printing field in histology, cytology and biomedical applications. 6) to gain access to the reflector. Operation 5.3 Alarm functions The Leica IP C is equipped with two different alarm functions: Instrument alarm The printer has a beeper that emits acoustic signals indicating important instrument states and functions. leica histology preparation sample automatic automated stainer services eosin hematoxylin staining system pathology integrated core ohsu protocol laboratories tissue immunohistochemistry You can still continue printing but maintenance must be carried out urgently. Remove the interior carton around the instrument. 5 empty "Mag. 1 empty 2 - Magazine No. Instrument Components and Specifications 3.3 Print specifications 22 Only standard histology cassettes that are reliably inserted into the magazines can be used in the Leica IP C. 23 22 Fig. 39 85 Push the small lever (69, Fig. If the message shown on the left is displayed, the driver has already been installed on your PC on a previous occasion (e.g. Relative humidity 80 % maximum - non-condensing Room temperature consistently between +15 C and +35 C Elevation: up to max. ment configuration conflicts with the PC configuration. Operation The "ADVANCED OPTIONS" menu Clicking onto the individual menu items opens up a pull-down menu to their right, where you can select the desired parameters. "Mag. 5. Allow the flash bulb to cool off before removing it. 2. 650 x 550 mm. 5. The system renders time-consuming manual cassette labeling work obsolete and is tailored to meet your requirements for permanent readability of good printing results. Instrument Setup 4.9 Exchanging the cartridge 4 5 85 64 Fig. 28.2 x 7.1 mm`. You will be responsible for paying for your own shipping costs for returning your item. 2000 m NN The instrument is designed for indoor use only. Barcode printed cassette used for tracking supports reduction of human error through automation and traceability. arka histology The package must be kept in a dry environment. When handling cleaning detergents, follow the instructions of the manufacturer and make sure all laboratory regulations in force in your country are complied with. Fig. Instrument Setup 4.10 Installing the printer driver This printer driver only runs under the operating systems Microsoft Windows NT 4.0, Windows 2000 and Windows XP. 6. 2 empty "Mag. 6. The port selected during installation (COM 2 in the example here) must be highlighted. 52 When clicking on the Source input field, an alphabetical list of all cassette supply options from all 6 magazines opens up. www.LeicaBiosystems.com Leica Biosystems Nussloch GmbH Heidelberger Strae 17-19 D- 69226 Nussloch Tel. 19 Caution! Features The description below refers to the installation of the driver under Windows NT. Cassette size (length) Insert without lid or with closed lid: > 41.3 mm Metal insert without lid or with closed lid: < 39.3 mm Metal strip and adhesive strip at front with open lid: < 80.0 mm Without any insert with open lid: < 77. controls the printer functions and the print jobs that are defined via the control software. Loosen the red screw-on cap one full turn but do not remove it yet. 70 Always use the cleaning swab for the print head once only. The test conditions stated below can therefore only serve as an outline for individual laboratory test specifications. If necessary, move flash bulb gently up and down. 56) The chute must be clean. Flash bulb dirty or defective. 2. 42 87 Fig. Call for Custom Quote! Caution! ReturnsOur policy lasts 30 days. Sensitive electronics components are located in this area. Insert the new flash bulb into socket (46, Fig. 59 (see also Fig. If you need to exchange it for the same item, send us an email at support@rankinwarehouse.com with your order number and product you wish to exchange and send your item to: 14515 Mackey Rd, Holly MI 48442, United States. Any steps that need to be carried out in a different way when installing under other Windows versions are also explained below. THERMO SCIENTIFIC EprediaPrintMate AS 150 Cassette Printer Cassette Printer For Sale, THERMO SCIENTIFIC EprediaPrintMate AS 450 Cassette Printer Cassette Printer For Sale, Auction Alert - Live Now: ZRG Medical Surplus Auctions August 12th, Access and use of this site is subject to the terms and conditions of our. 4. Unscrew the 8 screws (3 Fig. empty" flashing Magazine no. A resistant ink, specially designed for Leica Biosystems, makes imprints durable to chemical exposure and physical wear. Safety.. 9 2.1 2.2 3. empty" flashing The printer is waiting for an individual cassette to be placed in the feeding chute for printing. "00" will appear on the display for about 2 s. A print head clean is carried out and subsequently the print job is resumed. See a missing Specification? 5. Press CLEAN to rinse the print head; "00" will appear on the display. leica cassette printer histology ip rss updated 2009 The scope of the warranty is based on the content of the concluded agreement. Open the printer folder: START --> SETTINGS --> PRINTERS 2. Manual will be automatically added to "My Manuals", Symbols on the Transport Packaging and Their Meanings, 3 Instrument Components and Specifications, Printer Leica IP S Instructions For Use Manual, Printer Leica HistoCore PERMA S Instructions For Use Manual, Page 7: Symbols On The Transport Packaging And Their Meanings, Page 12: Instrument Components And Specifications, Page 26: Installing The Manual Unload Station, Page 27: Automated Unload Station (Optional), Page 28: Installing/Exchanging The Flash Bulb, Page 30: Filling And Inserting The Magazines. 2. for tissue cassettes. The printer is ready to print immediately. 9), measured from the bottom, can be 35 or 45. Troubleshooting 7.4 Changing the flash bulb Code "13" appears on the printer display when the flash bulb has reached its maximum service life. leica microtome 47 Fig. 1 Control panel Lid Covercartridge slot Unload station (manual) 4 6 Fig. 17): Open lid (4). Instrument Components and Specifications 3.2 Technical data General Approvals: The instrument-specific approval marks are located at the rear panel of the instrument, next to the name plate. The instrument setup date can be recorded on the white surface (65) on the front (Fig. 4. Operation 5.2 Display indications Display indication Magazine empty (in combination with "Mag. 3. + How to eliminate the problem: Determine the cause of the error using the error list (Chapter 7.3). 36 The printer is supplied with a cleaning cartridge (64) inserted. 6 empty If "MANUAL FEED" has been selected in the printer driver settings, "0" will appear in the display after the print job has been sent. Confirm the prompt pressing ERROR. The description below refers to Microsoft Wordpad, a program that is part of any Windows installation and therefore available on all PCs supported by the printer driver. Pressing ONLINE while a print job is in progress interrupts printing. Horizontal motor either incorrectly positioned or mechanically blocked. New ink cartridge: Press LOADED; the printer sets the ink level meter to 'full'. 3. *Prices are pre-tax. The angle (Fig. Pressing the CLEAN button briefly and then releasing it starts a print head clean (indicated by "00" being displayed). Depending on where you live, the time it may take for your exchanged product to reach you, may vary. 5. When the cleaning process is finished, press any key of the control panel to confirm. Batch job printing Next contact your bank. The following cassettes have been successfully tested with the Leica IP C. 3. 37) back down into its original position. 43 65 Fig. Important Information 1.1 Symbols in the text and their meanings Symbol for labeling electrical and electronic equipment in accordance with Section 7 of the German Electrical and Electronic Equipment Act (ElektroG). 6. Horizontal drive is mechanically blocked. Any number of trays between 1 and 10 can be inserted, as the printer counts the trays when they are inserted. Inkjet Printer for Tissue Cassettes The Leica IPC cassette printer easily integrates with all common LIS solutions for histology. manualzz The fuse holder is released and can be removed. If youve done all of this and you still have not received your refund yet, please contact us at support@rankinwarehouse.com. 2. Instrument Components and Specifications Requirements for bar code printing The quality and readability of printed bar codes will depend on several factors that include: Texture and quality of the printable surface of the cassettes. Instrument Components and Specifications 3.3.2 Print specifications Print resolution 26 Fig. the size of the imprintable zone of the cassette. Warranty and Service Warranty Leica Biosystems Nussloch GmbH guarantees that the contractual product delivered has been subjected to a comprehensive quality control procedure based on the Leica in-house testing standards, and that the product is faultless and complies with all technical specifications and/or agreed characteristics warranted. 2 Instructions for Use V 1. 4. Important Information REF Order number for standard delivery or accessories. histology ipc Please do not send your purchase back to the manufacturer. Color of the selected cassette or slide Barcode style (2D). 48). The printer cleans a print head at regular intervals (e.g. LED on: Printer is ready and waiting for a new print job. empty" flashing Magazine no. Instrument Setup 4.7 Filling and inserting the magazines 50 Inserting the strips Depending on the type of cassette used, additional inserts must be placed into the magazine (54) to guide the cassettes properly: This includes: 53 Metal insert 50 Adhesive strip (2 mm thick) 58 53 54 56 Metal strip Insert the metal strip (53) so that the angled part (58) touches the back panel (56) of the magazine (54, Fig. Additionally, it enables reliable archiving with quick and accurate case identification. by the manual unload station. 26) (the polarity marker (+) must not be visible any longer). Instrument Setup 4.1 Site requirements The instrument must not be operated in areas at risk of explosion. Never rotate the swabthis can damage the nozzle plate of the print head. controls the (optional) automated unload station. 4. Risk of injury. Prepared surfaces primed and painted with industrial-quality, chemical-resistant paint. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. 28.2 x 8.0 mm Cassette 45 : max. 6.2 mm high, Cassette 35 : max. 5. 1.1.1 Symbols on the transport packaging and their meanings The package contents are fragile and must be handled with care. 23 48 45 Fig. 5. : +49 - (0) 6224 - 143 0 Fax: +49 - (0) 6224 - 143 268 Web: www.LeicaBiosystems. 6. IMPORTANT! This accessory automates the manual slide removal process and helps avoid specimen mix-up errors. 33, left), so that no gaps can arise between the cassettes. The "Ink Empty" indicator LED goes out and "88" appears on the display. Instrument Setup Inserting the new flash bulb 86 44 46 85 86 47 Fig. 24 Check the instrument for transport damage. Push the small lever (69, Fig. Mechanical, pneumatic, and electronic assemblies disassembled, cleaned, restored, and reassembled, Worn assemblies, components and parts replaced with new assemblies, components and parts where needed, New components and parts can include pumps, motors, heaters, cables, belts, O-rings, diaphragms, gaskets, tubing, touch-pads, bottles, casters, doors, lids, fittings, valves, and other parts, Instrument reassembled to its original condition in accordance to OEM specifications, Assemblies function tested and adjusted for proper operation, System successfully calibrated with certified materials to ensure proper functionality, Quality Control testing conducted on established parameters using certified tools and control material. Remove cassette. 27 Fig. Cassette is stuck in the feeding chute. Refurbished with Warranty. 89 Fig. Of the set of power cords supplied, be sure to use only the one that is appropriate for the local power supply (plug must fit on-site wall outlet). Troubleshooting 7.3 Error messages Display code Troubleshooting solution Source of error Magazine output mechanically blocked. 8. Batch job printing: 15 cassettes/minute; single-cassette printing: 10 sec per cassette; for high throughput and optimized workflow. ElektroG is the law regarding the sale, return and environmentally sound disposal of electrical and electronic equipment. The print head (72) moves upward to a position approx. Transfer of a cassette from the chute to the cassette Remove cassette. 3) reacts (see also chapter 5.2). 6. 7. 23). In this case, be sure to select REPLACE EXISTING DRIVER. Cleaning and Maintenance Then pull out the location plate (70, Fig. 58) back down into its original position. Item must be in the original packaging (if applicable). In the selection window, select PRINTER IP C (blue mark). 7. Whether alphanumeric characters or 2D-Datamatrix barcodes, the print resolution is always satisfactory with good legibility. Safety 2.2 Warnings The safety devices installed in this instrument by the manufacturer only constitute the basis for accident prevention. Indicates the correct upright position of the package. The print head drying out is prevented, because the printer regularly rinses the print head. Automated unload station Your payment information is processed securely. The print head moves back to the rest position; the message "15" disappears from the display. The Leica IP C cassette printer has been designed for versatile printing of tissue cassettes, including cassettes with lids and two different imprint angles. Cleaning and Maintenance 6.4 Storing the printer If the printer is not used for a long period of time (up to three months), the following instructions are to be followed. 4. 69 Fig. LIS integration SN Designates the serial number of the instrument. Cleaning the instrument. 52 Cleaning the print head 1. 56 58 51 Fig. empty" flashing Magazine no. 2.1 Safety instructions These Instructions for Use include important instructions and information related to the operating safety and maintenance of the instrument. Operation ONLINE ERROR Leica IP C Interrupting a print job in progress. Cleaning and Maintenance Cassette guiding mechanisms Drying station (Fig. 64 Unscrew the red cap (85) one turn and slide the cartridge fully home. Fig. Any item not in its original condition or is damaged or missing parts for reasons, Any item that is returned more than 30 days after delivery, Item is broken, cracked, or damaged so that is is non-functional. The flash power supply is continuously being recharged. The imprint on each cassette remains readily identifiable throughout the histology process and storage period. Then contact your credit card company, it may take some time before your refund is officially posted. 5. 33 If taped cassettes are used, make sure the newly inserted stack aligns perfectly with the previously loaded cassettes (Fig. Ensure that the cover is not blocked, e.g. 7. Instrument Setup Filling and inserting the magazines (continued) 54 57 58 59 Fig. Cleaning and Maintenance Location plate (Fig. 1 cm away from the sealing lip (Fig. Remove the accessory box (7 includes accessories and packaging material) directly under the lid. Barcode printed cassette Check the sealing lip for damage. The online LED goes out. Press any key of the control panel to reposition the print head and make the printer ready to operate. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates. NOTE The information, numerical data, notes and value judgments contained in this manual represent the current state of scientific knowledge and state-of-the-art technology as we understand it following thorough investigation in this field. Faulty ejection of a cassette. 5. The multi-cassette unload station comes complete with 10 trays, all of which can be inserted simultaneously. For details on how to insert / replace the flash bulb, please refer to chapter 4.6. If the instrument remains connected to the power supply with the power on, the ink cartridge can remain in the printer up to its expiration date. Instrument Setup 4.8 Electrical connection The instrument must be connected to a grounded power socket. 44). 4Instrument Setup Unscrew the 8 screws (2 Fig. 8 Printing area The printing area parameters listed in the table below are defined in the printer driver. Operation Status messages (continued) Display 14 Prompt requesting maintenance If this message is displayed, the instrument will be due for maintenance within the next few weeks. Once the lifting table has reached its upper limit position, the LED in the button starts blinking. 3. If no print job is in progress: The print head is cleaned immediately after "00" has been displayed. Insert the cartridge into the slot. 41.3 x 28. 3. Instrument Setup 6. The instrument is de-energized after disconnection of the power supply through the power cable (power supply circuit breaker) - in emergencies, disconnect the power plug. 66 Clean the instrument completely, as described in this chapter. 70 71 The sealing lip (71) must be completely free of ink residue. Any menu items not described here are of no importance for the printer. LED flashing: A data transmission is in progress or a print job is being carried out. Mind the washer (42). Fig. For erroneous statements, drawings, technical illustrations etc. indicates current printer status and processes in progress. Instrument Components and Specifications 3.1 Overviewinstrument 2.1 2 1 3 5 1 2 2.1 3 4 5 6 - 12 Basic instrument Cassette magazines Magazine no. As the global market leader, no other histology cassette printer is more common in high-throughput diagnostic pathology laboratories. 4. 4. Switch the instrument on with the power switch (position "I" = ON). If you are shipping an item over $75, you should consider using a trackable shipping service or purchasing shipping insurance. Instructions for use Leica IP C Automated printing system for tissue cassettes Leica IP C, V 1.9 RevD, English 05/2013 Order No. No flash or flash duration too short. leica histology ipc cassette To complete your return, we require a receipt or proof of purchase. Therefore, the standard settings of all menu items not described here should remain unchanged. 4. 12) on the sides of the wooden box and loosen the cover. Close cover completely. Troubleshooting 7.1 Malfunctions If the printer malfunctions during printing, a corresponding error code is displayed and simultaneously the LED in the ERROR button starts flashing. 57 Open the printer lid and then press the CLEAN and LOADED keys simultaneously. Depending on the type of cassettes, each magazine holds up to 80 cassettes. microsystems ipc histology 3. 4. Troubleshooting 7.6 Replacing the secondary fuses Before replacing a fuse, always switch the instrument off and unplug from power supply. We also do not accept products that are intimate or sanitary goods, hazardous materials, or flammable liquids or gases. Instrument Components and Specifications 3.3.3 Printing bar code Printer technology Creating bar codes Printing readable bar codes depends on various factors that need to be taken into consideration in order to achieve results suitable for reliable and durable archiving. To be able to print, the cleaning cartridge must be exchanged for an ink cartridge. To insert/remove, hold the flash bulb as shown in Fig. Operation Selectable options in the PAPER --> SOURCE dialog box Fig. 5.2) Display code LED "Mag. The optional unload station automates the manual process and helps to avoid sequence mix up of printed cassettes 5. 14 0602 80101, RevD V 1.9 English 05/2013 Always keep this manual with the instrument. There is often some processing time before a refund is posted. Right-click on the icon of the newly installed printer, a quick menu opens up. Do not touch the chute during operation. The Leica IP C cassette printer uses a resistant ink that prevails against the chemicals used in your histology laboratory. 6. Instrument Setup 4.6 Installing/exchanging the flash bulb 41 49 42 Removing the old flash bulb Switch the instrument off and unplug it from power supply. 58). 4. There are certain situations where only partial refunds are granted (if applicable): Once your return is received and inspected, we will send you an email to notify you that we have received your returned item. There are 5 threaded holes (2 x item no. Includes slide racks and unload station. All laboratory personnel designated to operate this instrument must read these Instructions for Use carefully and must be familiar with all technical features of the instrument before attempting to operate it. empty" flashing Magazine no. Instrument Setup Exchanging the cartridge (continued) The sensor in the cartridge slot recognizes the presence of a new cartridge. 5 3.3.1 Requirements for cassettes 26 26 Fig. The Leica IP C and IP S systems are second generation printers for the labelling of all common specimen cassettes and glass slides with printing field in histology, cytology and biomedical applications. Operation 5.4 Printer driver settings With the Leica IP C cassette printer you can print cassettes from any Windows application allowing the user to individually configure the printing parameters. Defective fuses may be replaced only with the replacement fuses supplied together with the instrument. Instrument Setup Exchanging the cartridge (continued) 66 Fig. Automated printing system The location plate must be completely dry. Cleaning and Maintenance 6.1 Cleaning the instrument Prior to cleaning the instrument, always switch off power supply and unplug the power cord! 25); then push it carefully inwards as far as it will go (Fig. If the slides/cassettes you are currently using are not listed above, please contact your local Leica Microsystems representative. histology ipc 25 Make sure that the bulb is inserted correctly. Notes, i.e. Shipping costs are non-refundable. 44 Remove the ink cartridge (66) from the delivery carton and shake it a few times, then remove the protective foil. 10 s After changing the bulb, switch the printer back on. Click on PROPERTIES. 3. 56 Outer surfaces Clean the outer surfaces (including those of the automated cassette unload station) with a mild detergent and subsequently dry with a slightly moistened cloth. MANUAL FEED means, that individual cassettes will be placed onto the chute (12 in Fig. The PROPERTIES window contains several tabs; select the PORTS tab. Width Height Format Dots mm Dots mm Cassette 35 400 28,2 114 8,0 Cassette 45 400 28,2 100 7,1 Cassette type There are two different cassette types, which have a different angle, and therefore a different printable area.

Sitemap 2