Thanks for reading the counter! Posted: 10/3/2015, InyoPools Product Specialist Dennis R.
The gears seem to be spinning faster? Ed - Check out guide again to make sure you have the motor wired correctly. Find the breaker there. This was a piece of cake. Some of us are "handyman" challenged. Check out the diagram below, or see the wiring diagram which comes with a new timer, or is printed on the door of the timer box. Or other advice or explanation. Intermatic Pool Pump Timeclock Troubleshooting Tips Intheswim Pool Blog. You don't really need to disconnect all the wires shown in Step 3; just terminals 1 & 3 which connect to the timer. 5 Ways to Connect Wireless Headphones to TV, How to Use ES6 Template Literals in JavaScript, Introducing CSS New Font-Display Property, cara buka film bokeh full bokeh lights bokeh video, pioneer a 307r amplifier philips speakers sound test hq record, 2022 mernis sorgu iban sorgu suriyeli sorgu, collecting social media data for top ml ai data science related accounts on instagram, how to boost fps in csgo complete fps boost guide 2022, ibm selectric typewriters were your type 1984 tv commercial hd, unity challenge 1 car bonus features junior programmer pathway, download learning unreal engine game development von joanna lee, neda sadighi the association of families of flight ps752, woman started trading project with a bobby pin until she, islamabad international hospital research center highest, the 4 proven steps for achieving your goals achieve your, sifat allah yang wajib dan mustahil tahun 3, contoh surat rasmi tentang tidak hadir ke sekolah backup. None of the phillips screwdrivers I had would fit. Heres a real nice pictorial on how to replace an Intermatic timer motor, or mechanism. It should be 110V or 220V AC. The pump works in the bypass mode correct? we can go over how to fix the wiring. This will disengage the dial and allow you to spin it in either direction. Also your problem may be as simple as the dial was not engaged with the gears. There is a small port at the right above the yellow clock face. The black wire (line) is used as a path to terminal 2. Place the black plastic insulator back into the box and tighten the screw to keep it in place. If the timer clock is not turning on your pool pump timer, its either the timer itself has a fault or theres no power to the timer. The old motor was a WG1575-5 and so was the new one. Previous comment in order to get email response. Pleaseclickhere to viewIntermaticTimers. Swimming pool tips, reviews & how to mrdgvb1 on june 2, 2013 at 4:31 am. T101 is a 120V motor. watch these tips and tricks to make sure the timer is in fact. It does not matter which white cable goes to terminals 1 or 3. Posted: 6/23/2014, InyoPools Product Specialist Dennis R.
If youre not sure which is the best timer for your pool to get, we have a full blogpost for which Intermatic timer you should get for your pool. If the clock was already showing the correct time, check the On/Off Trippers (Pointers) are set to the correct time and are not loose. You can also find other insects such asAny animals or amphibians who are attracted by the instant watch box. If any of these issues occur your timer will not work properly. Fear not, my friend, for ASR Pro is here to save the day! This results in the pump coming on and running continuously. Reset the clock to the correct time. i have an intermatic t20004r and my timer is working because it is keeping the correct time. What is the problem? On the other hand, Intermatic timer motors can cost half the cost of a new mechanism, depending on the model. Remove the plastic insulator cover, and use an AC test meter to check for power on the terminals where the wires from the breaker connect to the time clock. While I'm not a certified electrician, we do have many here at TFP who may reply. A timer that switches on and off at the wrong times usually occurs after a power outage. Other smaller problems are more common, heres a list of some service calls Ive gone on over the years. When the flexibility on the circuit breaker box is disabled, that is, checked by an electric meter, all wires can be removed, 2 inputs and 2 outputs, ground wire. If the pump comes on, you definitely have power to the timer. You can replace the entire mechanism or the gears. I have a T104. Any new postings here are unlikely to be seen or responded to by other members. Remove the two screws, from terminals 1 and 3, that secure the two white clock motor cables in place. Also, you can try going to the bottom of your quick reply post where it says Go Advanced, and then down to where it says Manage Attachments. Posted: 8/10/2016, 92Keywest
Back when I was a young technician I was taught to always look for the easy things and use all my senses. Also be sure that the dial is not pulled out, but is engaging the gear behind the dial. If I have to tell you which terminals to measure, you shouldnt be doing this! Posted: 5/22/2017, Anonymous
One ground will be coming from the breaker and the other will be from the equipment. Posted: 10/1/2017, AySz88
Like Pablo, I also needed a small star screwdriver to remove the old motor from the back of the timer. Hi Phil, usually the OFF dog may not be fully pushed onto the dial, or if you examine it closely, it might be worn. If its not, it wont work properly. You can spray WD-40 behind the dial, on the lever and on the motor gears to lubricate. They are fairly straight-forward, but once in a while we do see some unusual wiring scenarios. But then again, Intermatic timer motors can be half the cost of a new mechanism, depending on the model. Terminals 2 and 4 are called the "Loads". Posted: 6/23/2017, InyoPools Product Specialist Dennis R.
Watch the video below if anyone needs a more complete illustration of how to set the 24 hour format. Basically youre eliminating possibilities until you find the cause. Pop-in a new timer mechanism, and replace the wires to the previous configuration. Could this be the problem? If you cant see an issue with the gears, then it could be the timer motor. The mechanism can then be removed by depressing a clip at the top inside of the timer box, just above the mechanism. I replaced the timer motor, the timer is keeping perfect time but when it comes time to turn on it won't turn on. Be careful with the exposed connections. With the new replacement, it's still doing the same thing, the timer is still not turning. See the point above if it is. If you have any other problems with the pool pump cook timer, please leave your answer below. When the power goes out, the timer stops. Tighten down all brass screws securely, to hold all wires firmly in place. is your rolling ball clock not working? Posted: 11/2/2013, Pablo
The device can then be removed by removing the clip from the top of the timer housing, directly in front of the mechanism. Posted: 8/27/2016, InyoPools Product Specialist Dennis R.
These were extremely helpful. Q: My Flexibility Has Been Lost And My Current Alarm Time Is Incorrect. See our guide on ". Posted: 10/24/2014, CB
A qualified person would check there is power to the timer and then bypass the timer to see if the pump worked. It only matters that one cable is on 1 and the other is on 3. Posted: 7/14/2016, InyoPools Product Specialist Dennis R.
has your oly beer barrel stopped moving? For wires connected to a specific pump or load, also connect green to GRD and white (neutral) to terminal A. So the dial is quite correct. This will disable the front and allow you to move it back and forth. They are: Heres how to troubleshoot a mechanical pool timer step-by-step: It goes without saying that you should be qualified if you intend on working with live power. If power is coming to the timer motor, you should be able to clearly see the gears moving through the small window. Install a new hourglass mechanism and replace the wires in the direction of the previous configuration. A flashlight will show the gears. If its not, then the timer will not turn on/off at the correct times. Switch the breaker off at the power board. We recommend these Intermatic timers for most pools:Intermatic T101 Intermatic T103Intermatic T104Intermatic T103. On occasion the two points that are used for setting the ON and OFF times for the pool pump get damaged or loosen. First you want to make sure there is actually power getting from the power board to the timer itself. I would try replacing the timer mechanism. Anonymous (T104) - Sometimes with older timers, the gears get sloppy and will bind during operation, even when the spin freely off the motor. With the power off at the breaker box, and checked with n electric meter, the wires can be removed, 2-in, 2-out, and the ground wire. if you like videos like this please subscribe to the what to look for when operating your intermatic time clock and diagnosis of most common problems. See our guide on ". Why?. The timer quit after a nearby lightning strike. Posted: 8/14/2015, Question
Check that the ON tripper is installed correctly. If power is reaching the clock, but the motor gears are not turning, that usually means either something is jammed in the gears (I once found a gecko tail), or the timer motor has burned out. My timer is running but the yellow dial stops when it turns the pump ON. For example, sometimes you can see a burnt wire or sometimes it may be as simple as the circuit breaker has been tripped. Check out the diagram below, or see the wiring diagram which comes with a new timer, or is printed on the door of the timer box. If not, the motor may be failing. Turn on the power at the circuit breaker. In fact, it can take less than 5 minutes. Any suggestions? If the yellow wheel stops turning but the manual switch still functions correctly, It may be due to one of two failures, the timer motor or the timer mechanism. Question - I would guess that your motor is a 220V motor if the gears are moving but I would check the supply voltage just to be sure. The reason is simple: TFPC (Trouble Free Pool Care) is a methodology, not a product that you must purchase. The Intermatic WG1573-10D clock motor should now be successfully installed if the yellow clock dial is turning. Just kidding, helpBut maybe this atmosphere could be vague? In this article, well cover what problems you may find with your Intermatic timer and how you can fix it without having to run to the store. Connect the cables running from the equipment to terminals 2 and 4. Even though my timer was not wired exactly as the one in the instructions, I was able to figure out how to do the job. This is hard to check if you are not qualified. in this video i'll show you how, We bring you the best Tutorial with otosection automotive based. Posted: 4/30/2017, InyoPools Product Specialist Dennis R.
Works great. You will have live wires exposed and they can kill you if you touch them. If you dont think the mechanism is the issue, move onto the next step. I have an issue with a T104 Intermatic Timer that the dial will not keep time, thus it will never turn on or off the pool pump. Replace the plastic insulator cover, turn on the power and observe the visual motor check. Heres a perfect list of some of the support calls Ive made over the years. Locate the two input power cables that come from the breaker. J. Johnson - It's not clear what you had replaced in your timer. Finally my screws were not phillips but one with star heads. Also known as an RCD (residual current device) in Australia and the UK. Window. Download this software and fix your PC in minutes. Heres a good photo of how to replace an Intermatic timer motor or perhaps a mechanism. Set the full current time on the middle hand of the era, pointing to five oclock. Any guidance on how to fix this? Greg G - It sounds like your need to replace T104 Mechanism. Connect one to terminal 1 and the other to terminal 3. With the motor removed the gears in the box spin freely. A: Use a large small flashlight to look at the engine control window next to the first timer gear. See our guide on ". Take the motor off of the back of the timing mechanism and turn the dial by hand to see if the small gear in the back that the motor engages move. For extra safety, shut-off the Pool breaker on the main home panel as well, and lock the panel, or place a large note, to prevent someone else from turning the breaker(s) back on while you are working. This is the first step to confirm if there is power or not. Just above the yellow clock youll see some holes. The pump turns on and off manually just fine.. Extremely useful. And yes, the WG1573-10D Clock motor is a compatible replacement for a WG1573-5. Note: it does not matter what color goes to 2 or 4. Clean the gears with a toothbrush if you see debris or gunk in them. Is it riddled with viruses and malware? Also check that you have 240V coming into the timer. Problemi Di Risoluzione Dei Problemi Del Timer Intermatic, Fehlerbehebung Bei Problemen Mit Dem Intermatic Timer, Problemas De Resolucion De Problemas Del Temporizador Intermatic, Problemes De Depannage De La Minuterie Intermatic, Problemas De Resolucao De Problemas De Temporizador Intermatic, Problemy Z Rozwiazywaniem Problemow Z Timerem Intermatic, intermatic sprinkler timer wiring diagram, 3. I see a little groove worn in the corner of the on/off switch where the off timer dog touches. It has to seat into the gears after you pull it out to set the time.into the gears after you pull it out to set the time. Q: My Time Slot Manual Lever Is Hard To Turn. Posted: 1/28/2015, Anonymous
I'm stumped.. Hello and welcome to TFP! Pull the cables away from the Intermatic mechanism. Hello. A: To set time A to the correct time, examine the outer edges of the large yellow dial and gently pull it towards you. Start with the easy checks. Hello , This is an inactive thread. After this has been removed, you can turn the breaker back on and measure for the voltage on the timer input. Hi, if you have a variable speed pump, you do not need to use the external timer anymore, but should program with the on-board pump timer. Turn the mechanism over and place one white cable onto terminal 1 and the other onto terminal 3. Connect the ground wires to the green screw located on the Intermatic timer mechanism. Intermatic timers are a great addition to your pool set up but they can go wrong. Watch These Tips And Tricks Before Replacing It. Posted: 5/2/2017, Greg G
Take them off and inspect them and look for twists in them. Yet another reason why timers dont work properly is the yellow clock wheel is not located or seated properly. Is this an indication that the motor is bad. i replaced the motor on my intermatic timer. A: Is the focus time arrow the one that says I am not twisting? You can replace it but its really just easier to replace the entire mechanism. There is no replacement on/off switch available, you would need a new T104 mechanism, unless you are able to melt some solder, or fix it with duct tape or something, lol! Grab it, pull it towards you, move it around then place it back down. Any suggestions? Make sure the middle time pointer is tight. When you let go of the dial, you want the gears to engage easily. I made sure the trippers were fully inserted and tight. Put a meter on the wires or trace them back to find out their voltage and source. Your T104 Clock motor is a 240V motor. This should not inhibit anyone but just be careful to use the right screwdriver. If not, use the circuit breaker to make sure the watch is plugged in, turn it on, then turn it on again. the clock works ok the on off triggers are ok but the lever switch is worn out. the switch is not being triggered on just off. Connect the green ground wire so that the GR screw turns green. Posted: 7/6/2015, Anonymous
If they are not moving then you have an issue. In my case, I replaced our pool timer with a new one (T104M 24Hr Mechanical Time Switch) because it was turning on/off (the timer was not turning). Hi Derrick, first try to reposition the timer tripper, making sure it is all the way on the dial. DSK - It sounds like the gears in the T104 mechanism may be jamming when it has to flip the switch. Now that you have it out take it back to Home Depot or wherever and exchange it for another one and see if that works. Then take the motor away for the timer gear and see if it runs by itself. 9 Problems With Intermatic Timers And How To Fix Them, Intermatic Pool Timer, Tips & Troubleshooting, website: swimmingpoollearning video index a list of all of my videos: pool timer not turning on or off? Posted: 6/11/2017, InyoPools Product Specialist Dennis R.
can you help me figure out why? Please clickhere to view the IntermaticTimer parts. Posted: 6/13/2017, J. Johnson
Now remove the terminal cover on the timer. If the timer manual switch isnt jammed and freely moves into the On and Off positions, then there is either no power to the timer, the timer itself has a fault, there is an issue with the wiring or the pool pump is faulty. It's an old house and an old timer, and the information on what tYpe of timer it was (220 or 110v) was unknown. cerylus - It is unlikely that your new timer is bad. learn more. If the power is on and the gears are not turning it is most likely the motor. Thanks for reading! Activate the minimum manually using the Minutter switch. Intermatic timer motors can be replaced, however if the timer is really new I would probably replace the specific Intermatic mechanism entirely. Please enter your username or email address to reset your password. For added safety, turn off the dedicated pool switch in the main building as a switchgear slot and block the snowboard or lay down a large piece of paper so that someone else cannot turn the switch (s) back on for a while. The Black (Line) wire would connect to terminal 2. Q: My Parking Meter Is Infested With Ants! Posted: 8/29/2016, cerylus
If it doesnt, there could be an issue with the clock face or gears. Posted: 6/29/2019, John kostanian
Having no power to your pool timer is a common problem and will occur because of three reasons: The first and easiest thing to check is the circuit breaker. A: If you have performed a full check of the gadget and determine that the engine or armor upgrades and gun are faulty, replaceThe timer program is easy to repair for a qualified technician. They should be straight, if not, replace them. A: The lever action should be crisp, not like its full of molasses. Most visitors online was 3404 , on Jan 24 2020, Texas, San Antonio/Marion, South-Central Area, Breaker flips when Intermatic timer starts, Intermatic timer replacement and wiring fix, With over 300,000 members, TFP is the largest and most influential pool & spa website on the Internet. Upload your pics to Photobucket (free), then copy & paste the IMG code for that pic from Photobucket to your TFP post. I can, however, hear an intermittent click as if the mechanism is trying to switch on. Hello.
Sitemap 12