Easy set up, half the price as new. Depending on the installation, the product should either be connected to the stack vent of the dwelling or vented (plumbed) directly outside. Connect the water supply line to the fill valve, located directly below the flush lever, on the bottom of the toilet tank. [{"displayPrice":"$831.99","priceAmount":831.99,"currencySymbol":"$","integerValue":"831","decimalSeparator":".","fractionalValue":"99","symbolPosition":"left","hasSpace":false,"showFractionalPartIfEmpty":true,"offerListingId":"MyeVZ7d%2FejMOS4Mgjhe99CNoo%2B54ZqKd5a3myrFc8SfCaj7w15I274pXLKQ%2FOkxJm8IYzKowTarQfd5geWFXFgWnk4qWz4BJ9cNUuWVADULgAaDEu10f%2F1lzPl8PX16SIKlcdsjBjS4uPf1k%2BjlKJbWX2B5xbWNE0A6NwM%2BqzOqOIKlq8y402BcOdQPw042s","locale":"en-US","buyingOptionType":"NEW"}]. Macerating toilet system is acceptable for indoor dry location use only. Ensure the macerating unit has both decorative covers installed and is plugged in with the power supply turned on. Check ValveThe discharge flange has an integrated check valve. Place the macerator in the desired location and connect all inlet and outlet waste piping to the unit. PumpProducts.com is dedicated to always offering the best value to our customers. Repetitively flush clean water and allow the macerator to clear debris. Typically drop per foot is adequate for a gravity drain. Solid object larger than 1/2 is trapped in the cutting basket of the macerator. The Ascent II macerating unit includes electronic controls and must be protected from direct water exposure during installation and use. All implied warranties, including those of merchantability and fitness for a particular purpose, are limited to three years from the date of purchase. Do not use an extension cord. Confirm the check valve is functioning properly; if not, repair or replace. Note: The actual distance between the p-trap of the additional fixture and macerator determines the necessary clearance to install the p-trap and elevation required to ensure a minimum pitch of 1/4 per foot drop. Visually check the macerating unit and any spare parts for damage. Then remove the hose, followed by the two screws. Battery: Battery must be installed after the macerator is connected to the AC power supply. Fatal electrical shock could occur. Do not remove any tags or labels from the pump or its cord. Water is not being evacuated from holding tank. Price Match guarantee is valid on price of item only, not on shipping and/or handling charges. The inflow is greater than the macerator can handle. Closely following these instructions will eliminate potential operating problems, assuring years of trouble-free service.No repair work should be carried out during the warranty period without prior factory approval. In the event of a power loss, the toilet can be used twice. Off-the-shelf toilet cleansers will normally not hurt the macerating unit. This pump has been evaluated for use with water only. A sink should be plumbed into one of the auxiliary inlets and not the discharge line of the macerator even if elevations would allow such an installation. on Liberty Pumps Ascent II-ESW Complete System with Round Front Toilet Installation Guide, Liberty Pumps Ascent II-ESW Complete System with Round Front Toilet, Liberty Pumps ProVore 1 HP Residential Grinder Pumps Installation Guide, Liberty Pumps Pro370-Series Simplex Sewage/Grinder Systems Installation Guide, www.LibertyPumps.com/Service/Replacement-Parts/, http://www.libertypumps.com/Services/Replacement-Parts, Austin Soft Close Toilet Seat Installation Guide, SHOWER TOILET BERNSTEIN Basic Installation Guide, Metra 95-6524B Jeep Liberty Installation Instruction, WINZO WZ5081 Elongated One Piece Toilet Installation Guide, AJAX 8706 KeyPad Wireless Touch Keyboard User Manual, Meizhou Hongfeng Arts Crafts 266285 BJ 57IN Snowman With Snowflakes Instruction Manual, AJAX 7661 StreetSiren Wireless Outdoor Siren User Manual, AJAX 17938 12V PSU for Hub/Hub Plus/ReX Power Supply Unit User Manual, AJAX 10306 Transmitter Wired to Wireless Detector Converter User Manual, ZERFUN G8 Pro Wireless Microphone System User Manual, Airrex Infrared Heater AH-200/300/800 User Manual, 2017 Toyota Camry Hybrid LE Fuse Box Diagrams, 2017 Mitsubishi Lancer 4WD Fuse Box Diagrams, Mitsubishi Lancer Passenger and Engine Fuse Box Diagram, Mira Honesty ERD Bar Valve and Fittings User Manual. Check flush valve and related components in the reservoir tank. Assemble the toilet in accordance with the installation manual(s) provided with it. Pump Products 2019 | Tel. The electrical power supply shall be located within the length limitations of the pump power cord, and for below grade installations it shall be at least 4 ft (1.22 m) above floor level. The unit will turn on shortly after the toilet is flushed or when water depth is achieved. The exterior of the macerating unit may be cleaned with a damp cloth and normal household cleaners. Both the discharge and vent plumbing should be secured using appropriate pipe clamping. Now, put a bathroom anywhere! To calculate the overall star rating and percentage breakdown by star, we dont use a simple average. If we cant repair it, well send you an Amazon e-gift card for the purchase price of your covered product or replace it. During cleaning or when using a plunger, the macerator could turn on. Pipework: All pipework should be copper, PVC, or CPVC. Accidental contact with electrically live parts, items, fluid, or water can cause serious injury or death. If storage is necessary, the pump should remain in its shipping container. This assumes a typical baseboard of 3/4 x 5-1/2 with 3/4 quarter round. NOTICE: Macerating unit must be located on same floor as connecting fixtures. plug the macerator back into the power source. Top subscription boxes right to your door, 1996-2022, Amazon.com, Inc. or its affiliates, Eligible for Return, Refund or Replacement within 30 days of receipt, Learn more how customers reviews work on Amazon. Unable to add item to List. After that, the unit should not be used again until the power is restored. Open the shut-off valve and let the toilet tank completely fill. Confirm vent is clear. Safety switch condition (no signal from safety switch; unit will not operate). Macerator starts to run and sounds normal (running) then stops after 5-10 min. Clear any buildup in the macerator holding tank that is preventing the flappers from opening. Vent in accordance with applicable plumbing codes.The macerator is not designed to support the discharge and vent piping; proper pipe supports are required. Installations may vary per local plumbing and electrical codes. The valve is held in place by a support backing plate that is also connected to the discharge hose. CleaningAll standard cleaners can be used just as with a standard conventional toilet. Only direct connections into sanitary waste systems shall be acceptable. Perfect for bathroom additions and remodeling without breaking concrete floors, the Ascent II can pump up to 25' vertically and 150 horizontally through a 1\" discharge pipe. The dated sales receipt must accompany the returned pump if the date of return is more than three years from the date of manufacture noted on the pump nameplate.The manufacturers sole obligation under this Warranty shall be limited to the repair or replacement of any parts found by the manufacturer to be defective, provided the part or assembly is returned freight prepaid to the manufacturer or its authorized service center, and provided that none of the following warranty-voiding characteristics are evident:The manufacturer shall not be liable under this Warranty if the product has not been properly installed, operated, or maintained per manufacturer instructions; if it has been disassembled, modified, abused, or tampered with; if the electrical cord has been cut, damaged, or spliced; if the pump discharge has been reduced in size; if the pump has been used in water temperatures above the advertised rating; if the pump has been used in water containing sand, lime, cement, gravel, or other abrasives; if the product has been used to pump chemicals, grease, or hydrocarbons; if a non-submersible motor has been subjected to moisture; or if the label bearing the model and serial number has been removed.Liberty Pumps, Inc. shall not be liable for any loss, damage, or expenses resulting from installation or use of its products, or for indirect, incidental, and consequential damages, including costs of removal, reinstallation or transportation.There is no other express warranty. The macerator has razor sharp cutters within this opening. The hose nipple can then be separated from the flange by pulling it outward. The green LED is solid when safety switch is properly activated.Hydraulic SystemCheck that the discharge pipe and vent pipe are not blocked.Water LeakageIf the macerating pump turns on intermittently without flushing the toilet or collecting water drainage from sink, shower, or tub, check for leakage from the toilet tank flush valve. The unit may pulse during a shower or draining a bathtub because the macerator can pump at a higher rate than the incoming flow. Long downward pitched runs of discharge piping, or piping where the point of discharge is at a lower elevation than the macerator unit, should be designed to prevent siphoning from the macerator tank.Friction: Friction losses from horizontal runs without 1/4 inch per foot pitch will reduce the amount of vertical lift the system is capable of handling. Macerator sounds normal and runs for 4 seconds, then after some time runs for 4 seconds. The initial horizontal run should not exceed 12 inches.Once the horizontal run is started, do not change directions in a vertical manner.Discharge: All discharge piping from the unit should run either directly vertical or in a horizontal plane (with a minimum 1/4 inch per foot drop) to the point of discharge. Price match does not apply to items promoted as limited time, limited quantity, while supplies last or any similar language. The auxiliary inlet couplers, Allen wrench, grease packet, clamps, and 9V battery are shipped in the access cover beneath the right access cover. Took about15 minutes to change over. Do not fully frame unit into a wall as access to macerator must be maintained.Toilet Placement: The toilet hold down fasteners should be located 16 inches from the wall and spaced 7 inches apart. The toilet discharge or extension pipe may be blocked. The Ascent II Macerating Toilet System is shipped in three separate packages: the toilet tank, toilet bowl, and macerating unit. Battery AccessThe battery receptacle is accessible under the left decorative cover. Comment document.getElementById("comment").setAttribute("id","ad22b9706310a7c2b1ebf0c4d32583c3");document.getElementById("afe6277d1c").setAttribute("id","comment"); Save my name, email, and website in this browser for the next time I comment. In doing so, the cutters are spinning at maximum speed (rpm) prior to fluid and debris reaching the cutting system. Do not use an extension cord to power the product. Please try again. Restarts after 30 to 60 min. Fatal electrical shock could occur. When roughing in, allow for the macerator.Discharge: Never discharge directly into an open drain, fixture, manhole or rainwater drainpipe. The new system features advanced Razor Cut technology for improved maceration of waste and a removable service panel that provides quick access to the cutter area without disconnecting the plumbing. The discharge flange contains a check valve that either requires cleaning or replacement. All electrical and safety practices shall be in accordance with the National Electrical Code, the Occupational Safety and Health Administration, or applicable local codes and ordinances. For example: 1 Schedule 40 PVC pipe is used for the discharge and runs horizontally for 1 ft, then turns 90, and rises 5 ft vertical. Carefully insert the new cutter blade onto the two pins. If you find a qualifying lower price online. Sanitary fixtures connected to the macerating system must be located on the same floor level. Follow all the safety instructions in manual(s) and on the pump.Failure to do so could result in serious injury or death. Place the toilet over the holes in the floor. Discharge and Vent FlangesBoth the discharge and vent flanges are fastened to the main cover and can be removed by unscrewing the four fasteners and pulling the flange away from the main cover. The store will not work correctly in the case when cookies are disabled. Refer to Figure 3. The alarm automatically resets once a normal cycle is performed. NOTICE: Do not use an air admittance valve or a mechanical spring-loaded venting device, as these devices are one-way valves. Verify Green LED is steady, indicating normal operating condition. The toilet or discharge extension might be blocked. Pliers may be required if unit has been stored.Both the discharge and vent flanges are shipped from the factory in the horizontal orientation. It is not intended for kitchen waste, nor is it intended to be used for the disposal of wastewater from such pumped appliances as dishwashers and clothes washers. The toilet works as a conventional flushing toilet and needs no special maintenance with normal use.Any regular bathtub (up to 100 gallons) or shower can be used.When installing these fixtures, build a 6 inch high platform for the fixture to be placed. Full content visible, double tap to read brief content. : 1-800-429-0800 | Fax. Next, the discharge and vent flanges should be separated from the main cover by removing 4 screws from each.The main cover can then be detached from the tank by removing the fasteners on the periphery of the tank. The cutter blades are designed and rigorously tested to last indefinitely without need for service or replacement in ordinary applications. 7000 Apple Tree AvenueBergen, NY 14416ph: 800-543-2550fax: 585-494-1839www.LibertyPumps.com. Safety switch is broken; consult factory. Pump shall be properly grounded using its supplied grounding conductor. Avoid dipping or trapping, which may cause the buildup of residual solids and subsequent blockage.Bends: Wherever possible, long sweeping bends should be used.
Sitemap 7